| Hydraulic Press |
- The hydraulic pump and hydraulic cylinder are separated for easy replacement
- Max. Force: 24T
- Manual operation
|
| Max. Working Pressure |
| Gauge Displayed Pressure Value (MPa) |
5 |
10 |
15 |
20 |
25 |
30 |
35 |
40 |
45 |
| Actual Force Applied on the Hydraulic Cylinder (Ton) |
4 |
6 |
9 |
11 |
14 |
17 |
19 |
22 |
24 |
- The actual force applied to the Hydraulic Cylinder (Ton) is equal to the force applied to your working piece
- For calculating the actual pressure (MPa) applied to your working piece, please follow the equations below:
- P = T/(πr^2) x g x 10
- P: Pressure (MPa) applied to your working piece
- T: Force (Ton) applied to the Hydraulic Cylinder
- g: Standard gravity. g ≈ 9.8 m/s2
- π: ~3.14
- r: Radius (cm) of the working piece
- *1 Metric Ton = 1000 kg; 1 MPa ≈ 10 kgf/cm2
|
| Pressure Gauge |
- Measuring Accuracy is ± 1.5 T
- The reading from pressure gauge is different with that applied on samples.
|
Heated Platen Area
|
- Platen Area: 135 mm x 135 mm
- Material: Harden Cr12MoV alloy for 500°C version ( SS310 for 750oC version)
- Surface: Flattening with CNC grinding
- The parallelism between two plates: < 0.05 mm within 10"x10" area
- Plate surface roughness: < 2 microns
|
| Max. Travel Distance |
- 58 mm (that means the thickest sample should be below 58 mm).
- Do not raise the bottom cylinder (piston) more than its maximum traveling distance (80 mm)
|
| Max. Working Temperature |
- 450°C continuous with water cooling
- 500°C for less than 30 minutes with water cooling
- 750°C version is available upon request at extra cost.
- 650°C continuous with water cooling.
|
| Heating Rate & Cooling Rate |
|
Water Cooling
|
- Two 1/4" water pipe connectors.
-
A water chiller is required but not included.
- Our KJ5000 water chiller is available.
- An optional electric hydraulic pump for automatic pressure control is also available. (Pic below )
|
| Temperature Control |
- Two digital controllers are installed in one box with 30 segments programmable and auto-tune faction
- Temperature accuracy ±2°C.
|
| Power Requirement |
- 208 - 240 VAC, 50/60Hz, single phase
- 2.5 kW max.
- 15 A circuit breaker is required for 220 V, 5' length power cable included, but no plug
|
| Compliance |
- CE Certified for the whole furnace
- NRTL (UL 61010) or CSA Certification is available upon request, additional charges will apply
|
| Application not |
This hot -press can be used inside glovebox with Ar and N2 gases |