Induction Heater
|
- Working Voltage: 220V AC, 50/ 60Hz, Three Phases (380VAC, 3phase available upon request)
- Working Current: 10~86 Amps (100A breaker required)
- Max. Input Power: 25 KW
- Output Frequency: 30 - 80 kHz
- Duty Cycle: 100%
- Induction Coil: 150mm(OD) x 140mm(ID) x 65mm(H)
- Air Cooling: Rear Fan
- Protection: Automatic water pressure, over-temperature, and overpower protection
- Refractory Assembling: Complete refractory assembling made of alumina, including bottom crucible support, crucible holder, and cover
|
| Timer Control |
- Automatic timer control or Manual control selectable
- Manual Control: by Foot Pedal
- Automatic Heating Time: 1-99 Seconds
- Automatic Dwell Time: 1-99 Seconds
- Automatic Cooling Time: 1-99 Seconds
|
Temp. Controller & Thermocouple (optional)
|
- Precision digital temperature controller with Automatic PID tuning
- 30 segments programmable for controlling heating and cooling rate as well as dwell time.
- Overheating & thermocouple failure protection.
- +/- 3 ºC temperature accuracy.
- +/- 3 ºC temperature accuracy.
- Thermocouple: C type ( 1/4"x10"L ) ( pls click here to order spare as consumable )
- Continuous Working Temp. Range: 1000ºC~1900ºC
- Max. Working Temperature: 2000ºC (for less than an hour)
- Max. Heating Rate:
- 4ºC/second (1000ºC-1200ºC)
- 3ºC/second (1200ºC~1500ºC)
- 1ºC~2ºC/second (1500ºC~2000ºC)
|
Water Cooling
|
- Flowrate: >10 L/Min
- Pressure: ≥0.2 MPa (29 Psi)
- Tap water is acceptable, but using a Recirculating Water Chiller is highly recommended. Please click here to order separately
- Protection: Overpressure and over-temperature switch
- Recirculating water Chiller (58 L/min) is required as an option at extra cost
|
Compliance
|
-
NRTL or CSA Certification is available upon request at extra cost, please contact us for a price quote. Certify standards include: 1) Induction heater: UL61010-1 & UL499; 2) Vacuum Pump: UL1450; 3) Water Chiller: UL61010 & UL1995
|
Application Notes
|
-
Attention: Protective inert gas must be continuously filled throughout the experiment in order to protect the graphite crucible and C thermocouple. The gas flow rate should be limited to < 200ml/min
- The induction coil may inerted into the glovebox via special KF40 feedthrough with inert gas
|