| Power Supply |
- Input: 480 VAC, 3ph, 27 KW, 50/60Hz
- Optional: 400 VAC, 3 ph.
|
|
Melting Chamber
|
- Water-cooled stainless steel high vacuum chamber.
- Ultimate vacuum: 7e-7 torr.
- Practical vacuum 5e-6 torr
- Leak rate <3.75 x 10^-4 (torr·l)/s
- Chamber size: 280×350×440 mm
- Tinted observation windows
- Hinged front door
- A wobble stick is built-in for sample flipping without breaking the vacuum
- ISO160K port for vacuum generation.
|
|
Water-cooled Copper Hearth
|
Three types of water-cooled copper hearths available ( pls choose one when order
- Single copper hearth for melting 300 g steel with electromagnetic stirring.
Cavity 1: Ø80×25 mm with electromagnetic stirring Cavity 2: Ø35×17.5 mm Cavity 3: Ø35×17.5 mm Cavity 4: Ø35×17.5 mm
- Copper hearth for vacuum casting
- Cavity 1: Ø40×20 mm
- Cavity 2: Ø40×20 mm
- Cavity 3: Ø60×20 mm with electromagnetic stirring.
- Cavity 4: Ø50×10 mm for vacuum casting, up to Ø8×75 mm casting rod.
3. 170 mm dia x 20 mm depth, 277 ml capacity
- Tilt casting is available upon request
- Customized crucible and mold designs are available upon request.
|
|
Tungsten Electrode
|
- Water-cooled ceriated tungsten electrodes, Ø12 mm
|
|
Power Supply
|
- IGBT inverted power supply, up to 25 kW.
- Voltage 0 - 34 V DC
- Current: 20-630 A DC
- 630A / 34V @ 60% duty cycle
- 488A / 29V @ 100% duty cycle
- HF ( High frequency ) start
|
| Pressure Gauge |
- Inficon PCG554 Pirani Capacitance Diaphragm Gauge
|
|
Vacuum System
(Optional)
|
- 700 L/s Pfeiffer Vacuum turbopump station with a ISO160K manual gate valve
- 240 L/min rotary vane backing pump with an oil mist trap and an intake filter.
- Cold cathod / Pirani full range pressure gauge 3.75×10^-9 - 1000 torr
- A vacuum foreline connection is included in the optional package.
|
Water Chiller (Optional)
|
- KJ 5300 recirculating water chiller with 16L/min water flow and 6K BTU/hr cooling capacity
- Digital Temperature Control: 5 - 30ºC adjustable with ± 0.3 °C accuracy
- Refrigerant: R410-a
|
Working Gas (Optional)
|
-
High-purity inert gas with at least 5N purity (>99.999%) is required (not included)
- 5% Hydrogen + 95% Argon gas may be used to prevent oxidation during the melting process
- High-purity Ti sample melting may help absorb oxygen a lot
- A two-stage pressure regulator must be installed on the gas cylinder to limit the pressure to below 3 psi for safe operation. Click here to learn to installation of a gas regulator
|
| Compliance |
- CE certified
- UL/CSA certification by NRTLs is available at an extra fee.
|