Furnace structure & Vacuum Chamber
|
- A dual Heater, two temperature controllers, and two-channel gas flowmeters are integrated into a mobile aluminum alloy frame
- The chamber is made of high purity fused quartz tube
- Quartz tube size: 11" OD/10.8" ID x 9" H
- Carbon fiber felt as thermal insulation
- The vacuum flanges are made of Stainless Steel 316
- Overall dimension: 850(L)×745(W)×1615(H) mm
|
|
|
- Top Flange with one KFD-25 vacuum port and two gas outlets (1/4" pipe required) can slide up or down manually to load and unload substrate and evaporated material easily
- The bottom flange has one KFD-25 vacuum port with two gas inlets (1/4" pipe required) and needle valves
- The flange is sealed by double silicone o-rings and can achieve maximum vacuum pressure of 10E-2 Torr by a quality mechanical pump and 10E-5 Torr by a molecular pump
- Precision anti-corrosion digital vacuum gauge is in standard package (Since 2016.03.24).
|
|
Gas Flow Meters
|
- Two float meters are installed on the control panel with a measurement range of:
- 16 -160 mL/m
- 400 - 4000 mL/m (for purging purpose)
|
Heater and Sample Holder
|
- Two shortwave IR lamps as heating elements for fast heating.
- The distance between two heaters is adjustable from 10 - 50 mm
- The heaters are made of stainless steel with a water cold jacket to reduce heat radiation and allow for fast cooling
-
3" round wafer holder is built-in with the top heater to load the substrate
- One high thermal conductive AlN plate (3"Dia x 0.5mm Thick) is included, which shall put on the back of the substrate to make it heated uniformly
- One 3" graphite plate can be used alternatively for the AIN plate, please click the picture below to order.
- Halogen Light Heater replacement is available at extra cost, please click here to order.
|
Temperature Controller
|
- Two precision digital temperature controllers with 30 segments programmable offer independent controlling of top and bottom heaters
- Each controller has PID auto-tune function to protect heaters from overshooting and alarm function to avoid overheating and the thermal couple broke
- PC communication interface & software is installed
|
Working Temperature |
- Maximum temperature for each heater: <= 650ºC
- The maximum temperature difference between two heaters: <= 300ºC depends on the spacing between two heaters:
- Spacing 30mm Max. temp difference: 315ºC @ heating bottom only
- Spacing 40mm Max. temp difference: 350ºC @ heating bottom only
- Spacing 50mm Max. temp difference: 395ºC @ heating bottom only
|
| Heating & Cooling Rate |
- Heating: < 8ºC/s ( heating single heater only )
- Cooling: < 10ºC/s (600 - 100ºC) Max.
|
| Thermal Couple |
Two K-type thermal couples (exposed) are installed on top and bottom heaters separately |
| Working Voltage |
208 - 240VAC, single-phase, 20A air breaker |
| Power Requirement |
2200W total ( 1100W for each heater ) |
Optional |
- One vacuum pump is required. Please order separately by clicking the first picture from the left below. Vacuum level can reach <= 10E-2 torr by the mechanical pump
- If you run corrosive gas, please consider using an anti-corrosive dry pump, as shown in the second picture from the left below ( Pfeiffer pump from Germany ) at extra cost
- You may order a recirculating water chiller for saving water sources separately
- You may choose a digital MFC gas delivery system by clicking the first picture from the right below
|
| Compliance |
- CE Certified
- NRTL or CSA Certification is available upon request, additional charges will apply
|
Note
|
- The tube furnaces with quartz tubes are designed for use under vacuum and low pressure < 0.2 bars / 3 psi
- Vacuum pressures may only be safely used up to 1000°C. The flow rate for gasses should be limited to < 200 SCCM for reducing thermal shocks to the tube..
|