Effective Rolling Width
|
200 mm
|
| Roller Material & Size |
- High strength hardening steel with hardness with RC > 52
- The Roller surface is plated by Cr for anti-corrosive
- Size: 96 mm Dia. x 220mm W
|
|
Roller Gap

|
- 0~ 10 mm adjustable
- Note The gap tolerance may vary with temperature raising as below
- RT - 100°C: 0.008 - 0.01 mm
- 100 - 150°C: 0.02 - 0.03 mm
- 150 - 250°C: 0.03 - 0.05 mm
|
|
Dial Gauge Accuracy
|
0.01mm |
Rolling Thickness & Hardness |
- Min. 0.01 mm
- Max. 10.0 mm
- Max. the hardness of sample to be rolled: < 40 HRC
|
Heating Temperature 
|
- Two digital temperature controllers with 30 segments programmable for control two rollers separately
- 250°C maximum ( <= 1 hrs suggested)
- Recommended Heating Rate: 1.3°C/minute
- Two heating elements are installed
- Power of each Heating Element: 1000W
- Temperature Control Accuracy: +/-5°C
- Two spare heating rods are included for replacement. Pls click pic left to see specs.
|
|
Power
|
- AC 208 - 240V, single phase, 50/60Hz, 2.5 kW
- 10-ft power cord without a plug.
- A 3kW transformer is available for use under 120V, 30A.
|
|
Motor
|
- High torque motor with reducing gear, which can run under Ar gas safely
- Rated power 100W
- Digital speed Display: 0~26 mm/s
- Digital controlled with constant output power
|
|
Options
|
- For Roll to Roll, please consider below R2R device (click picture 1 & video to order)

- We can modify the rolling press into a vertical position at the extra cost
|
Compliance |
- CE Certified
- MET certificate is available upon request at extra cost
|
| Warnings |
- Do not touch the surface of the rolling part of the machine when the rollers are heated up or running.
-
Due to the influence of working environments, the temperature on the roller surface may be different from the display on the controller. You may calibrate the temperature by TC-calibrator-LD, and refer to the instruction here from time to time to ensure heating temperature accuracy
- Multi-step thickness calendaring needed: While calendaring the sample sheet, make each calendaring decrement of 0.02mm compared with the sheet's original thickness.
- Never calendaring decrement over 0.02mm compared with original sheet thickness each calendaring.
- Never roll materials with hardness > 40HRC
- Clean roller surface after each use and lubricate rollers when not used to avoid corrosion
-
It is not allowed to use any MTI product in Class I environments (flammable gasses & vapor).
|