Features and principle
|
- Modular design for easy installation without professionals
- Made of stainless steel plate with 3 mm thickness
- Uniformly remove moisture without "dead corner " and "channel effect"
- Dew Point: -40ºC ~ 79 ppm) under the condition that has no de-gas or de-vapor equipment inside and measures in the center of the dry room with one operator.
- Power saving with quiet operation
- Only allow one or two person to operate inside the dry room
|
| Dry Room Dimension |
- Internal Area: ~ 9 square meters ( 96.8 square feet )
- Operation Area: 2,920 mm L x 2,920 mm W x 2,100 mm H (Including buffering room 780 mm L x 650 mm W x 2,100 mm H)
- Dry room size: 3,000 mm L x 3,000 mm W x 2,400 mm H (maximum customized size of 3*6 m is available upon request)
- Dehumidification system size: 2,000 mm L x 1,000 mm W x 1,800 mm H
- Lighting and power cords are built inside the dry room
- Noise level: < 55 dB
- You need an air-conditional room with PVC or rubber floor carpet to place all devices above
- The temperature inside the dry room: It is dependent on the outside temperature. The temperature may reach 20oC if the outside temperature is 25oC
- If you need a noise level < 30 dB, the water cold recirculating water chiller can be used at an extra cost.
|
|
Dehumidifier
and Power requited
|
- AC 220 V +/- 10%, 50 / 60Hz, Three phases
- Installed Power: 23 KW Max. (Dehumidifier: 10 kW, Water Chiller: 4.5 kW, Reserved for Dry Room: 8 kW). In fact, the operation power for the dehumidifier and water chiller is 8 kW and 4 kW, respectively.
- 40A air-breaker for power panel of dehumidifier and water chiller {I = P/ (1.73 * U * 0.85)}.
- We highly recommend two separate circuit breakers for the dehumidifier (25A) and water chiller (15A) on the wall power source.
|
| Water Cooling Requirement |
- <= 7 °C cooling water
- Cooling capacity: >12 KW
- Water flow: : > 3 m³/h
- Coolant circulation port for inlet and outlet: 25 mm ( DN25 ) ( PVC tube: 25 mm ID x 32 mm OD)
- We may supply the recirculating water chiller for you at an extra cost if there is no cooling water system in your lab.
- Water Cooling System size: 1,350 mm L x 600 mm W x 1,250 mm H
|
| Control System |
- Purification limitation: Water concentration -40ºC Dew Point with the empty room
|
| Air Flow |
- 1,000 CMH (cubic meter per hour)
- 588 CFM (cubic feet per minute)
|
| Air Turn Over |
|
| Noise level |
|
| Application Note |
- Dry room + Glovebox combination scheme is also available upon request to process air-sensitive materials:
|
Note and Warning
|
- Must wear Clean room cloth to enter the dry room as picture left for quick recovery of dew point
- Please keep the cloth in the dry room inside to keep dry ( baffle room )
- Please allow 20 - 30 minutes recovering the dew point to-40ºC when one person enters the dry room
- -50ºC dew point is available upon request at an extra cost
|