| Working Voltage |
- 208-240VAC, 50/60Hz, single phase.
- AC 110V version is available via a 2000W transformer.
|
| Power |
|
| Stacking Slot Size |
-
Max. Size: 200 mm L x 150 mm W (customer should inform us the stacking die size).
- Maximum thickness for the stacking electrodes is 15 mm
- Other small stacking slot sizes are avilble upon request
|
| Stackable Layers |
|
| Stacking Speed |
|
| Max. Electrode Thickness |
- Piled up thickness < 15 mm
|
| Aligning Accuracy |
- ±0.5 mm for stacked electrodes
|
| Acceptable Separator Roll Size |
- I.D>3'' (76mm)
- O.D<9.8'' (250mm)
|
| Stacking Fixture |
- One set of 80 x 50mm stacking die fixtures is included for immediate use.
-
If you need different size electrode stacking, please inform us before order. We will make it for you at an extra cost. Allowable customization size: Max. 200mm x 200mm; Min. 80 mm x 50 mm Each size cell needs one mold
|
| Vacuum Pump |
- An Oilless Vacuum pump (28L/min, 140W) is built-in to enable the vacuum suction function of the electrode pick-up/stacking manipulator.
|
| Suggested Air Pressure |
- 0.5 - 0.8 MPa (Air compressor is not included in the standard package. Please click here to order)
-
Attention: If a gas cylinder is used instead of an air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation. Click here to learn the installation of a gas regulator.
pic1pic2
|
| Compliance |
- CE Certified
- NRTL certificate is available upon request at an extra cost
|
| Application Notes |
- Note: please confirm electrode sheet size before order ( each mold only fit with one size electrode )
- To get the special shape of the electrode for stacking, you may need MSK-180-AM Auto electrode die cutting machine, and use MSK-120 Pouch Forming Machine to form the pouch.
-
This machine can be put in a glovebox and operated in Ar gas
|