Power
|
- 9.5 KW, 208 - 240V single phase, 50/60Hz
- AC 208, 400V, 480V, 3-phase is also available upon request.
- 10-foot power cord is included. No power plug.
|
|
Pressure
|
|
|
Heating Chamber
|
- Five-side heating for best temperature uniformity.
- High-quality alumina fibrous insulation
- Kanthal Fe-Cr-Al resistance heating wire
- Hermetic steel chamber for vacuum and gas atmosphere control
- Sample load: < 35 kg.
- Vacuum level: ( please let us know your requirement)
- 10-1 torr for use of oxygen or inert gas by standard thermal insulation material
|
|
Heating Area
|
- 400x 400x 400 mm (~ 16"x16" x16"), 64 Liter
|
|
Uniform Heating Area
|
- Uniform Area 300 × 300 × 300 mm ±2℃ @ 800 °C
|
|
Working Temperature
|
- <1100°C, continuously
- <1200°C, max with < 1 hr heating time.
|
|
Temperature Controller
|
-
FA-YD518P-AG PID temperature controller
- 30 programmable temperature segments
- Built-in over-temperature alarm and thermocouple failure alarm
- +/- 1 ºC temperature control accuracy
- RS485 PC communication port
|
|
Eurotherm Temperature Controller (optional)
|
- Upgrade to Eurotherm Temperature Controller with enhanced temperature control of fluctuation <+/- 0.1ºC
- This package includes a Eurotherm 3000 series temperature controller and a communication cable (RS485 - USB)
|
|
Thermocouple
|
- Omega Dual K Type Thermocouple 12"L 1/4" OD
|
|
Heating Rate
|
- < 10°C / min recommended
- 20 °C/min Max.
|
|
Vacuum
|
|
Gas flow control
|
- Two 8 L/min float flow meters are installed in the front
|
| Vacuum Pump |
- 240 L/min rotary vane vacuum pump, YTP-550.
- Power 110V or 208-240VAC, single phase, 50/60Hz.
|
Water Cooling
|
- A 16L/min recirculating water chiller
- Over-temperature alarm
- Water chiller failure alarm
- Power 110V or 208-240VAC, single phase, 50/60Hz.
|
|
Retort (optional)
|
- Stainless steel 310 retort is also available for debinding purposes.
- Retort dimensions 300 × 300 × 300 mm
- The retort comes with its own gas inlet and outlet.
|
| Working Gases |
- Inert gas
- Air
- Oxygen
- 5% hydrogen non-flammable inert gas
|
Compliance
|
- CE Certified
- NRTL (UL61010) or CSA certification is available at extra cost.
|
|
Warning & Note
|