Structure
|
- The hybrid film applicator includes two parts, which are made of stainless steel.
- 100 mm width doctor blade with dual micrometers to adjust film thickness at the range at 0.01 mm - 5 mm (click Picture 1 to see details)
- 50 mm width slot head, which can be fixed on the doctor blade to coat film thickness from 0.005mm - 0.02 mm (click Picture 1 to see details) which includes ( see picture left column)
- 2 pcs of 0.2 mm thickness Shim
- 2 pcs of 0.3 mm thickness shim
- 2 pcs of 0.4 mm thickness shim
- 1 pcs PTFE tube ( 1/8"OD x 2.175 mm ID)
- Join connectors to pump and slot die
- Other widths slots die heads (10 or 30 mm) may be installed on the doctor blade upon request (Pic.2)
- The PTFE buffering pad installed on the bottom of the doctor blade to reduce friction (Pic. 3)
-
Pic.1 Pic.2 Pic.3
|
Micrometer Head
|
- Digital micrometer head accuracy: +/- 0,001 mm
- The micrometer heads are built-in doctor blade frame to adjust the gap between the slot die and the substrate
|
| Optional Coater |
- The most suitable for the hybrid film applicator is MSK-AFA-HC100 coater. because it has a lapped glass surface and < flatness of +/- 2 microns. Please click the Pic. 1 below right to order separately
- Slot die is removable if using the doctor blade head for tape coating
- For slot die coating, you may order a Syringe Pump as Pic. 2 below:
Pic. 1 Pic. 2 |
| Application Note |
- Coating thickness is not dependent on or equal to the gap between the slot die head and substrate.
- Usually, the gap shall be larger than the coating thickness. Coated thickness is strongly dependent on slurry viscosity, coating speed, and flow speed. ( Lower viscosity, low flow rate, and low speed will result in the thinner film. Please practice finding the best parameters which suitable for you
- Example 5% carbon+ polymer, viscosity: 500mPa·s, substrate: Al foil of 16 um,
- Gap: 200 um, Slurry feeding rate:: 0.1 ml/minute , Coating speed: 12mm/s
- Dry coated film thickness: 5 um +/- 1 um
|