Induction Heater
|
- Working Voltage: 208~240V AC, 50/ 60Hz, Three Phase
- Working Current: 96 Amp (100A breaker required)
- Max. Input Power: 35 KW
- Output Frequency: 80 - 200 kHz Adjustable
- Duty Cycle: 80%
- Air Cooling: Rear Fan
- Protection: Automatic water pressure, over-temperature, and overload protection
|
Induction coil and Heated Tube
|
- Water cold induction Coil: 135 (ID) x 300 L, mm
- Fused Quarzt tube: 100 (OD) x 90 (ID) x 700 (L) mm)
- Graphite Tube: 40(OD) x 30 (ID) x 300 (L) mm
- Thermal insulation: High-purity carbon felt
- YSZ ceramic coating for graphite tube ID is available upon request for carbon-sensitive material
|
Vacuum seal flanges
|
- Vacuum flanges: Left side: IR temperature sensor with gas-inlet and pressure gauge
- Right side: KF 25 port for vacuum pump and the gas outlet valve
- Vacuum level: 10-2 torr by a mechanical pump and 10-5 torr by turbopump
-
Optional: Digital vacuum gauge up to 4x 10-5 torr is available at the extra cost.
|
Temp. Controller & Thermocouple
|
- 30 segments programmable for precise controls of heating rate, cooling rate, and dwell time.
- Temperature sensor: IR senor ( made in Germany )
- Max. working temperarure: 2300ºC ( < 60 minutes )
- Continuous Working Temp. Range: 1200ºC~2200ºC
- Constant temperature zone: 60 mm ±5
- Max. Heating rate: 40/min≤160030/min1600-2300
- Max. Cooling rate: 30/min1000—2300
- +/- 2 ºC temperature accuracy.
|
Water Chiller
|
- Water cooling with > 116 L/minute flow rate is required for cooling the induction coil.
-
You may click the picture left to order a recirculating water chiller.
|
Vacuum Pump
|
- Vacuum level: 5x10e-2 torr by the mechanical vacuum and 10e-5 torr by turbo-pump
- Please click the left to order a vacuum pump
|
| Compliance |
- NRTL Certification is available upon request at extra cost, please contact our sales representatives for a price quote.
|