Induction Heater |
- Working Voltage: 220VAC three phases) 50/ 60 Hz.
- Working Current: 5-25 Amp (30A breaker required)
- Output Frequency: 50-300 kHz Adjustable
- Max. Output Power: 10KW
- Required Water Flowrate: >16 L/min
- Two Unit: the Power control unit is separated with the induction heating unit
|
Copper Crucible
|
- Dimensions: 27 mm(OD) x 10 mm(ID) x 12 mm depth
- Water cooling inside
- Required Water Flowrate: >40 L/min
- Max. Load: 5 g for metallic or alloy
- Required water: > 40 L/min.
|
Optional Recirculating Water Chiller and Gas required
|
- If you don't have water cooling line, please consider our recirculating water chiller 58L/min at extra cost.
- High purity Argon gas ( > 5N) tank with pressure regulator is required, but not included. Click here to learn more about the installation of a gas regulator. ( please click the picture below right to order a correct gas regulator )
|
| Quartz Tube & Vacuum Flange |
- One quartz tube included: 32 mm(OD) x 28 mm(ID) x 160 mm(L
- One pair of Vacuum Flanges with double high-temperature silicone O-rings
- Max. Vacuum Pressure:
- 10-2 torr by the mechanical pump (included)
- 10-5 torr by molecular pump
- Bottom flange is controlled by an electric motor for easy sample loading and unloading
|
Vacuum Pump |
- One two-stage mechanical pump with exhaust filter is included
- KF25 adapter, bellow, and valve are included for immediate use
- The vacuum pump is integrated into the movable steel case
-
|
| Application Notes |
- The Melting System are designed for using under vacuum and low pressure < 0.02 MPa / 0.2 Bar/ 3 PSI
-
Attention: A pressure regulator must be installed on your input gas tank and have the output gas pressure set below 3 PSI with the gas maintained in a continuous flowing condition. Gas build-up with pressure levels exceeding over 3 PSI may cause irreversible damage to the furnace chamber.
- Never heat the furnace while the gas release valve is closed and a positive pressure condition exists within the furnace chamber.
- The flow rate for gases should be limited to < 200 SCCM ( or 200ml/min )
-
WARNING
Read the manual carefully. Monitor and control the inside pressure of the reaction vessel at all time during operation. Otherwise, failure of operation may result in irreparable damage.
|
| Compliance |
NRTL or CSA Certification is available upon request at extra cost |