Digital Controlled Infusion Syringe Pump
|
Features |
- Easy to use keypad interface
- Holds small or big syringes up to 60 mL
- Pumps continuously until you stop the pump
- The infusion rate can be changed while pumping
- Remembers previous settings on power-up
- Power failure mode allows the pump to continue pumping after a reset
- Syringe purge mode
- Displays total volume dispensed in mL or µL units
- The maximum pumping rate of 25 mL/min with a 60 mL syringe
- Precise reproducible flow rates
- Selectable infusion rates units: mL/hr, µL/hr, mL/min, µL/min
- Infuses Only Does not withdraw, volume target, or have computer interface
- Infusion Syringe Pump with optional Heatable Glass Syringe is available at extra cost
|
| Input Power |
100 -240VAC, 0.75Amps |
| Dimension |
|
100°C 20ml Heatable Glass Syringe with Temperature Control Unit
|
Max. Power
|
23 W |
Max. Temperature
|
100°C ( Higher temperature up to 250°C is available upon request ) |
| Thermo Couple |
K type |
Temperature Controller
|
- The controller uses PID via SSR power control
- Single point setting controller
- Over-temperature protection and alarm allow for operation without attendant(s).
- +/- 1 ºC temperature accuracy.
|
| Dimensions |
260 x 230 x 120 mm (L x D x H) |
Syringe
|
20ml Glass syringe OD: 24mm ID: 20mm Total Length with a booster: 145mm
|
| Operation instructions |
|
| Compliance |
CE certified NRTL and CSA certification is available upon request at the extra cost
|
| Application Notes |
- Pre-metered Horizontal-Dipping Process
- Such a syringe pump can precisely control the volume of the solution per unit coating area been fed into the gap between the cylindrical barrier and the glass substrate.
- Doctor-Blade (or Wire-Bar) Coating: Such Syringe Pump can be used for adding a solvent at various concentrations. By using multiple syringe pumps, you can add an ingredient in a certain weight ratio to a mixed solution. Similar to the Horizontal-dipping Process, the blended organic solution is introduced into the space between the barrier and the substrate by such pumps' capillary action. The Doctor-Blade is transported horizontally at a given constant velocity, a thin solution layer is then spread and formed evenly on the substrate.
-
Dip Coating: Wet solution coating such as dip coating has been the most popular method for solution-processed devices.
- DIY an Ultrasonic Spray and Electrospinning device
|