Power Source for Arcing
|
- 4 NRTL certified digitally controlled power sources are included and stacked on a mobile cart.
- Each power source is output DC pulsing AC selectable
- Input voltage: 208 - 240 VAC selectable, single phase, 50/60Hz
- Output: 18 V / 250 A at 60% duty cycle - 240 V input
- Minimum DC current output: 5 A
- Total power requirement for 4 power sources
- 15KW in total
- 4 output plugs are required and each one with a 40A breaker
|
| Arc melting Heads |
-
4 arc melting heads are fed through into the vacuum chamber.
- Each head consists of a 4 mm diameter tungsten rod with a water-cooling sleeve
- The position of each arc melting head is adjustable in length and angle
- Capable melt 100 g alloy ( Fe based ) or 30g ( W based )
|
Copper Hearth
|
- Rotatable copper hearth with water cooling jacket is built inside a vacuum chamber
- The cavity dimension of the copper hearth: 100 mm Dia x 15 mm depth
- Rotating speed: 1 - 20 rpm adjustable with digital display
- > 58L/min recirculating water chiller is required, but not included , please click the picture below to order
|
Vacuum Chamber
|
- Water-cooled SS304 vacuum chamber with dimensions of Φ 300 mm × 320 mm H
- Φ150mm front door for easy sample loading and retrieving
-
One tinted observation windows with 100 mm Dia for monitoring the melting process
- KF 40 port is built in to connect a mechanical vacuum pump
- ISO63 port with blind flange is built in to connect to a turbopump
- two 1/4 fittings with needle valves are built-in for inert gas inlet and outlet
- Pressure range: 10 -6 torr to 900 tor
- Leaking rate: < 5.0E10-7 Pa.l/S
|
Vacuum Pump (Optional)
|
- The vacuum level is dependent on the vacuum pump used:
- 10^-3 torr via a mechanical/roughing pump. (Roughing Pumps)
- 10^-6 torr via a turbopump. ( Turbopump must direct connects to chamber )
-
|
| Compliance |
- CE certified
- UL/CSA certification by NRTLs is available at an extra fee.
|
Application & Warning Notes
|
- A two-stage pressure regulator must be installed on the gas cylinder to limit the pressure to below 3 psi for safe operation. Click here to learn the installation of a gas regulator (Pic.1)
- Must Wear Welder Glass or Auto Welding Shade while observing the Arc while welding.
- The unit is designed for arc melting operation under tiny positive pressure or low vacuum (0.01 – 0.11 MPa pressure, or positive 0.01 MPa to negative 0.09 MPa pressure). Never operate the unit at high pressure!
- During the arc melting operation, never allow the electrode to touch the material or the copper crucible! Do not operate the mechanical manipulator during the melting process.
|